| Article #114 - Is the Twinax portion of my 5794ip working correctly? |
|---|
| Updated:10-25-2006 - Views: 631 |
|
How can I tell if the Twinax portion of my 5794ip is working correctly? If the power LED is on steady, other than a brief flash off and on every five seconds (referred to as a "heartbeat"), and the twinax devices are powered on, the appropriate Line 1 or Line 2 LED will indicate the following. If the Line 1 or Line 2 LED is ON with a heartbeat, at least one Twinax device on the appropriate line is responding to polls. If the Line 1 or Line 2 LED is OFF with a heartbeat there are no Twinax devices on the appropriate line responding to polls. If the Line 1 and Line 2 LED's are out, with no heartbeat, the Twinax communication processor in the 5794ip controller is no longer functioning. |
|
Use the form below to submit a comment on this article for inclusion into the knowledgebase. End-users are welcome to submit articles relating to any category in the knowledgebase. Submit a comment in response to the knowledgebase article. Please keep the response professional, the content may be modified by the Knowledgebase Administrator. Before posting the comment will be reviewed and may be edited for brevity, structure and content. |