Article #234 - Additional FormPort Flash Printed Error Messages
Updated:02-13-2006 - Views: 712
If the FormPort Flash detects an Error while reading a Form it will re-assign the Trigger Line and the Trigger Column numbers so that the Form will be unavailable for printing (any Entry that has a Line/Column number that is greater than or equal to 700 is ignored). This temporary ?reassignment of numbers? does not change the Job/Form Trigger Entry that is contained in the printer?s ?forms.cfg? file that is used by the EWS Configuration Tool..

The cause of the Error is indicated on the FormPort Flash Configuration Page in the ?Printer-Resident Form Definitions? section. The FormPort Flash re-assignment of ?Trigger Line? and ?Trigger Column? numbers will correspond to one of the following Errors:

*** INVALID PAGE-PARAMETER IN FORM FILE ***
Line/Column 701 Page 1 is Too Wide
Line/Column 702 Page 1 is Too Long
Line/Column 703 Double-Byte Not Supported Here
Line/Column 704 Page 1 Width is Less Than Page n Width
Line/Column 705 Page 1 Length is Less Than Page n Length

*** BAD STRUCTURE IN FORM FILE ***
Line/Column 801 Error Reading DOCUMENT Structure
Line/Column 802 Error Reading AS400 Structure
Line/Column 803 Error Reading PAGE Structure
Line/Column 804 Error Reading TEXT Structure
Line/Column 805 Error Reading GRAPH Structure
Line/Column 806 Error Reading IMAGE Structure
Line/Column 807 Error Reading BARCODE Structure
Line/Column 808 Error Reading TEXTFIELD Structure
Line/Column 809 Error Reading IMAGEFIELD Structure
Line/Column 810 Error Reading BARCODEFIELD Structure
Line/Column 811 Error Reading DELETESPDATA Structure
Line/Column 812 Error Reading FONT Structure
Line/Column 813 Error Reading IMAGEDATA Structure

*** BAD OR MISSING FORM FILE ***
Line/Column 901 Error Opening Form file
Line/Column 902 Error Reading Form file
Line/Column 903 Invalid Form Header
Line/Column 904 Invalid Form Version
Line/Column 905 Error Reading Structure Header
Line/Column 906 Invalid Form Header
Line/Column 907 Unrecognized Structure
Line/Column 908 Invalid Structure Header
Line/Column 909 Couldn?t Allocate Form Memory