| Article #366 - Why do all devices connected to the 5794ip controller keep going down? |
|---|
| Updated:03-28-2006 - Views: 484 |
| All devices configured on the 5794ip controller using the Anynet protocol will drop connection with the host when any one of the displays or printers are powered off.
Resolution of this problem is accomplished by varying off all devices, then varying off the xxxxxrmt or 5494 controller created by Anynet. Change the 'Switched Disconnect' value to *No which will keep the host from dropping the connection when a device is powered off. |
|
Use the form below to submit a comment on this article for inclusion into the knowledgebase. End-users are welcome to submit articles relating to any category in the knowledgebase. Submit a comment in response to the knowledgebase article. Please keep the response professional, the content may be modified by the Knowledgebase Administrator. Before posting the comment will be reviewed and may be edited for brevity, structure and content. |