8019 / 8029 Switch Settings

Top Group of Switches
Twisted Pair Booster
Switch 1
Switch 2
Switch 3
Switch 4
Normal
Not Used
ON
Not Used
Not Used
Passive booster
Not Used
OFF
Not Used
Not Used
Note: Use Normal for twinax or active hub cabling. Change this selection only when experiencing problems with a passive twisted pair hub.
Language
Switch 5
Switch 6
Switch 7
Switch 8
Multinational 00
OFF
OFF
OFF
OFF
US / Canada 01
OFF
OFF
OFF
ON
Austria / Germany 02
OFF
OFF
ON
OFF
Belgium 03
OFF
OFF
ON
ON
Brazil 04
OFF
ON
OFF
OFF
Canada French 05
OFF
ON
OFF
ON
Denmark / Norway 06
OFF
ON
ON
OFF
Finland / Sweden 07
OFF
ON
ON
ON
France 08
ON
OFF
OFF
OFF
Italy 09
ON
OFF
OFF
ON
Japan English 10
ON
OFF
ON
OFF
Portugal 12
ON
ON
OFF
OFF
Spain 13
ON
ON
OFF
ON
Spanish Speaking 14
ON
ON
ON
OFF
United Kingdom 15
ON
ON
ON
ON

 

Rear Group of Switches
Address
Switch 1
Switch 2
Switch 3
0
OFF
OFF
OFF
1
ON
OFF
OFF
2
OFF
ON
OFF
3
ON
ON
OFF
4
OFF
OFF
ON
5
ON
OFF
ON
6
OFF
ON
ON
7 (Test Setup)
ON
ON
ON

Orientation Switch 4 Switch 5
Landscape OFF ON
Portrait ON OFF
Host COR override enabled * OFF OFF
Host COR override disabled ON ON

Printer Mode Switch 6
IBM PPDS OFF
HP PCL ON
 
Automatic Orientation Switch 7
Enabled * ON
Disabled OFF
* For normal COR operations switch 7 must be ON and switches 4 and 5 should be OFF.
 
Hex Print Switch 8
Disabled OFF
Enabled ON